Atexxo Manufacturing

Specialist in Atex and IECEx Solutions

  • en
  • nl
  • de
  • ru
  • fr
  • it
  • es
info@atexxo.com
+31(0)186 601 299
    
  • About us
    • Contact
    • Order information
    • News
    • Jobs
  • Ex Protection
    • General Technical Requirements (Ex) EN 60079-0
    • Flameproof (Ex d) – EN 60079-1
    • Pressurisation (Ex p) – EN 60079-2
    • Increased Safety (Ex e) – EN 60079-7
    • Intrinsic Safety (Ex i) – EN 60079-11
    • Non sparking (Ex n) – EN 60079-15
    • Encapsulation (Ex m) – EN 60079-18
  • Products
    • Ex Proof AC Units R32
      • EX Proof AC units
      • Ducted ATEX AC units R32
      • ATEX AC Units R32
    • EX Proof Smart Phones
      • ATEX iPhone SE
      • ATEX Watch S5
      • EX Zone 1 iPhone 11
      • ATEX iPhone 11
      • ATEX iPhone XR
      • ATEX iPhone XS
      • ATEX iPhone XS Max
      • ATEX Galaxy S10
    • ATEX Air Conditioners
    • Ex Proof Tablets
      • ATEX iPad Mini 4
      • ATEX iPad Mini 5
      • IECEx Ipad Mini 5
      • ATEX iPad 9.7
      • ATEX iPad 10.2
    • Explosion proof iPhone 6
    • Explosion proof iphone 8
    • Explosion Proof ATEX Zone 2 Intrinsically Safe iPad Mini 4
    • ATEX explosion-proof panel heaters
    • Atex zona 2, climatizzatori sistema split antideflagranti
    • ATEX / IECEx Cable Glands
      • EX Glands Normal Cable
      • EX Glands Armor Cable
      • EX Locknuts
      • EX Breather
      • EX Drain valve
      • EX Blindplug
    • Climatizzatori antideflagranti, ATEX, EAC-EX zona 2 sistema split
    • EX proof VRV Cooling
    • EX Window Air Conditioner
  • Manufacturing / Conversion
    • IP-Proofing / Tropicalisation
  • Project Solutions
  • Downloads
  • Contact
Atexxo / Ex Protection / Non sparking (Ex n) – EN 60079-15

Non sparking (Ex n) – EN 60079-15

This type of protection is suitable for Zone 2 or 22 hazardous areas, and can apply to a large range of equipment.
Generally any electrical device that does not have potentially sparking contacts can be accommodated.

To prevent sparking on pcb’s  and other critial electic components creepage and clearance distances need to be adressed carefully ATEX coating can be used to reduce risk of arcs and Sparks between conductors . In most cases the enclosures need to be dust/water tight to avoid tracking across live circuits.

In addition, specific requirements apply to certain recognised types of equipment, such as motors, luminaires and batteries.
Equipment with potentially sparking contacts such as pcb’s, potentiometers, relays or switches, can be protected in a number of ways:

  • Encapsulation

    Suited to higher power circuits or where creepage and clearance distances on a circuit board are below the required minimum.

  • Sealed

    The sparking device is sealed in an enclosure so the flammable atmosphere cannot gain access.

  • Restricted breathing

    The enclosure may contain either hot components butno sparking components, or sparking components but with low internal air temperature rise. This method relies on a tight gasket seal on the enclosure joints.

  • Enclosed break

    Applies to small enclosures where the design of the enclosure joints prevents an internal ignition from transmitting to the flammable atmosphere outside. Similar to Ex d but without flamepath design requirements.

  • Energy limited (see intrinsic Safety (Ex i) – EN 60079-11)

    Similar to intrinsic safety, the energy available at potentially sparking parts is limited to prevent an ignition occurring. Suitable for circuit designs where detailed knowledge of the design is available and modifications can be accommodated.

Downloads

clients_explosion_proof_air_conditioners

Products

Mobile Phones

  • Explosion Proof ATEX Zone 2 Intrinsically Safe iPhone XR
  • ATEX iphone XS explosion proof Ex
  • ATEX iphone XS Max explosion proof Ex
  • ATEX Samsung Galaxy S10 explosion proof Ex
  • Explosion proof iPhone 6 ATEX
  • Explosion proof iPhone 8 ATEX
  • Explosion Proof ATEX Zone 2 iPhone SE Increased Intrinsically Safe
  • Atex Apple Watch S5 explosion proof (pdf)
  • ATEX iphone 11 Explosion proof
  • EX Zone 1 iPhone 11

Air Conditioning

  • Ex Proof AC Units
  • ATEX-AIRCO-SPLIT-UNIT-EX (2-7 kw)
  • EXPLOSION-PROOF-AIR-CONDITONER (7-14kw)
  • EXPLOSION-PROOF-VRV-COOLING (22-33kw)
  • ATEX-AIR-CONDITIONING-TOSHIBA
  • EXPLOSION_PROOF_AIR_CONDITIONING_EX
  • ATEX-WINDOW-AIR-CONDITIONER
  • ATEX-WINDOW-AIR-CONDITIONER-2
  • Ducted ATEX AC units R32
  • Ex Proof AC Units R32

Tablets

  • Explosion Proof ATEX Zone 2 Intrinsically Safe iPad Mini 4
  • Explosion Proof ATEX Zone 2 Intrinsically Safe iPad Mini 5
  • Explosion Proof ATEX / IECEx Apple iPad mini 5 for Zone 1
  • ATEX ipad 9.7 explosion proof Ex
  • Explosion Proof ATEX Zone 2 iPad 10.2 Intrinsically Safe

Other

  • Cable-Glands-ATEX -IECEX-DNV-GL

Certificates

EPS 20 ATEX 1 129 X

EPS 20 ATEX 1 240 X

EPS 20 ATEX 1 248 X

IECEx EPS 20.0048 000

IECEx EPS 20.0040 X

ATEXXO QAN QAR 19ATEXQ0080

ISO_9001_2015

OCTANS_IMQ 13 ATEX 018X issue no.1

IECEx_CERT_DEK_18.0026_0

EX_IA_CERTIFICATE

EAC_EX_CERTIFICATE

ORION_CESI_13_ATEX_033X_Ext_2

NORMA_IECEx_IMQ_13.0006X_1_2014-09-09 signed

DNV Marine Approval

e-14044_CABLE_GLANDS

e-14047_LOCKNUTS

e-14045_PLUGS

Search

    
info@atexxo.com
+31(0)186 601 299
  • Contact
  • Sitemap
  • en
  • nl
  • de
  • ru
  • fr
  • it
  • es

© Copyright 2015 atexxo.com · All Rights reserved · Admin