Atexxo Manufacturing

Specialist in Atex and IECEx Solutions

  • en
  • nl
  • de
  • ru
  • fr
  • it
  • es
info@atexxo.com
+31(0)186 601 299
    
  • About us
    • Contact
    • Order information
    • News
    • Jobs
  • Ex Protection
    • General Technical Requirements (Ex) EN 60079-0
    • Flameproof (Ex d) – EN 60079-1
    • Pressurisation (Ex p) – EN 60079-2
    • Increased Safety (Ex e) – EN 60079-7
    • Intrinsic Safety (Ex i) – EN 60079-11
    • Non sparking (Ex n) – EN 60079-15
    • Encapsulation (Ex m) – EN 60079-18
  • Products
    • Ex Proof AC Units R32
      • EX Proof AC units
      • Ducted ATEX AC units R32
      • ATEX AC Units R32
    • EX Proof Smart Phones
      • ATEX iPhone SE
      • ATEX Watch S5
      • EX Zone 1 iPhone 11
      • ATEX iPhone 11
      • ATEX iPhone XR
      • ATEX iPhone XS
      • ATEX iPhone XS Max
      • ATEX Galaxy S10
    • ATEX Air Conditioners
    • Ex Proof Tablets
      • ATEX iPad Mini 4
      • ATEX iPad Mini 5
      • IECEx Ipad Mini 5
      • ATEX iPad 9.7
      • ATEX iPad 10.2
    • Explosion proof iPhone 6
    • Explosion proof iphone 8
    • Explosion Proof ATEX Zone 2 Intrinsically Safe iPad Mini 4
    • ATEX explosion-proof panel heaters
    • Atex zona 2, climatizzatori sistema split antideflagranti
    • ATEX / IECEx Cable Glands
      • EX Glands Normal Cable
      • EX Glands Armor Cable
      • EX Locknuts
      • EX Breather
      • EX Drain valve
      • EX Blindplug
    • Climatizzatori antideflagranti, ATEX, EAC-EX zona 2 sistema split
    • EX proof VRV Cooling
    • EX Window Air Conditioner
  • Manufacturing / Conversion
    • IP-Proofing / Tropicalisation
  • Project Solutions
  • Downloads
  • Contact
Atexxo / Ex Protection / Increased Safety (Ex e) – EN 60079-7

Increased Safety (Ex e) – EN 60079-7

The most common equipment protected by increased safety are transformers, motors, luminaires, cells, batteries, terminals and wires. It is not appropriate for electronic components or  sparking devices such as switches. Increased Safety relies upon a dust/water tight enclosure to avoid tracking across live circuits. A large number of manufacturers produce increased safety enclosures, terminals and junction boxes.

Important Design Parameters

  • Uninsulated, live components are subject to special protective requirements. Air and creepage gaps are wider than is generally the case in industry. Special conditions apply to the required IP enclosure protection.
  • More stringent requirements apply to windings; mechanical strength, insulation, and resistance to high temperatures. Minimum cross sections are stipulated for winding wire, the impregnation and reinforcement of coils, and thermal monitoring devices.

Applications

Installation material such as Marshalling and junction boxes, terminal compartments for heating systems, batteries, transformers, ballast, and squirrel cage motors.

Increased Safety (Ex e) – EN 60079-7

The most common equipment protected by increased safety are transformers, motors, luminaires, cells, batteries, terminals and wires. It is not appropriate for electronic components or sparking devices such as switches. Increased Safety relies upon a dust/water tight enclosure to avoid tracking across live circuits. A large number of manufacturers produce increased safety enclosures, terminals and junction boxes.

Downloads

clients_explosion_proof_air_conditioners

Products

Mobile Phones

  • Explosion Proof ATEX Zone 2 Intrinsically Safe iPhone XR
  • ATEX iphone XS explosion proof Ex
  • ATEX iphone XS Max explosion proof Ex
  • ATEX Samsung Galaxy S10 explosion proof Ex
  • Explosion proof iPhone 6 ATEX
  • Explosion proof iPhone 8 ATEX
  • Explosion Proof ATEX Zone 2 iPhone SE Increased Intrinsically Safe
  • Atex Apple Watch S5 explosion proof (pdf)
  • ATEX iphone 11 Explosion proof
  • EX Zone 1 iPhone 11

Air Conditioning

  • Ex Proof AC Units
  • ATEX-AIRCO-SPLIT-UNIT-EX (2-7 kw)
  • EXPLOSION-PROOF-AIR-CONDITONER (7-14kw)
  • EXPLOSION-PROOF-VRV-COOLING (22-33kw)
  • ATEX-AIR-CONDITIONING-TOSHIBA
  • EXPLOSION_PROOF_AIR_CONDITIONING_EX
  • ATEX-WINDOW-AIR-CONDITIONER
  • ATEX-WINDOW-AIR-CONDITIONER-2
  • Ducted ATEX AC units R32
  • Ex Proof AC Units R32

Tablets

  • Explosion Proof ATEX Zone 2 Intrinsically Safe iPad Mini 4
  • Explosion Proof ATEX Zone 2 Intrinsically Safe iPad Mini 5
  • Explosion Proof ATEX / IECEx Apple iPad mini 5 for Zone 1
  • ATEX ipad 9.7 explosion proof Ex
  • Explosion Proof ATEX Zone 2 iPad 10.2 Intrinsically Safe

Other

  • Cable-Glands-ATEX -IECEX-DNV-GL

Certificates

EPS 20 ATEX 1 129 X

EPS 20 ATEX 1 240 X

EPS 20 ATEX 1 248 X

IECEx EPS 20.0048 000

IECEx EPS 20.0040 X

ATEXXO QAN QAR 19ATEXQ0080

ISO_9001_2015

OCTANS_IMQ 13 ATEX 018X issue no.1

IECEx_CERT_DEK_18.0026_0

EX_IA_CERTIFICATE

EAC_EX_CERTIFICATE

ORION_CESI_13_ATEX_033X_Ext_2

NORMA_IECEx_IMQ_13.0006X_1_2014-09-09 signed

DNV Marine Approval

e-14044_CABLE_GLANDS

e-14047_LOCKNUTS

e-14045_PLUGS

Search

    
info@atexxo.com
+31(0)186 601 299
  • Contact
  • Sitemap
  • en
  • nl
  • de
  • ru
  • fr
  • it
  • es

© Copyright 2015 atexxo.com · All Rights reserved · Admin